Solar Substation Technician: Moving Into MV and HV Work

Past the inverter, a solar plant becomes a power plant: transformers, breakers, relays and a switchyard. Here is how O&M techs move into that higher-voltage, higher-paid work.

Jobs In Solar Tech Editorial7 min read

Key takeaways

  • The AC side of a utility-scale plant, from the step-up transformers to the switchyard, is where the highest-paid field roles in solar O&M sit.
  • One large owner-operator posts its high voltage technician role at $95,000 to $110,000 and asks for at least five years of HV experience.
  • BLS puts the May 2025 median for powerhouse, substation and relay repairers at $103,020, with 10 percent projected growth through 2035.
  • OSHA 1910.269 governs much of this work: job briefings, lockout/tagout, minimum approach distances and arc-flash assessments.
  • The usual path in is switching and clearance duties at your own site, then breaker, transformer and relay exposure, then a formal credential such as NETA.

Most solar O&M training stops at the inverter. DC strings, combiner boxes, inverter faults and trackers fill the first few years. But a utility-scale plant does not end there. Past the inverters sit step-up transformers, a medium-voltage collection system, breakers, protective relays and a switchyard or substation tying the whole plant to the grid. The solar substation technician who can work safely on that side of the plant is one of the most valuable and best-paid people on site.

This guide explains what medium- and high-voltage work looks like at a solar plant, what the rules require, what employers ask for, what it pays and how a DC-side tech realistically gets there. If you are still deciding which direction to specialize, see our ranking of O&M specializations by pay first.

What sits on the AC side of a solar plant

Inverters convert array DC into AC at a relatively low voltage. According to the overview of PV power stations on Wikipedia, inverter output typically lands somewhere around 480 to 800 volts AC, and three-phase step-up transformers raise it to 10 kV and above, because grids run at tens or hundreds of thousands of volts. From there the plant's layout usually looks like this:

  • Inverter step-up transformers at each inverter skid or block, often oil-filled.
  • A medium-voltage collection system of underground cable, and sometimes overhead lines, carrying power from the blocks to a central point.
  • Collection breakers and switchgear that can isolate individual feeders.
  • A project substation with a main power transformer that steps up again to transmission voltage, protected by relays and breakers.
  • A gen-tie line and switchyard connecting to the utility.

Clearway Energy's current high voltage technician posting gives a sense of scale: the role covers overhead lines, underground cable, substation switching equipment, power instrumentation and transformers up to 230 kV.

What a solar substation technician actually does

Duties vary by owner, but the Clearway posting for its Mojave, California site lists a representative set:

  • High voltage maintenance, troubleshooting and repair
  • Switching and grounding under approved switching orders
  • Maintaining and testing MV and HV breakers and disconnects
  • Tracking relay calibration dates, supervising contracted relay testing and filing the final reports
  • Planning outage work: permits, lockout/tagout, contractors, tools and parts
  • Training site staff and contractors in safe practices and keeping test logs

The skills list is just as telling: underground cable fault locating, battery maintenance, protective relays, transformer maintenance including oil sampling and dissolved gas analysis, and thermography. Notice how much of this is managing work, not just doing it. Relay testing and major transformer work are often done by specialist contractors, and the in-house HV tech is the one who plans the outage, writes the switching and watches the contractor.

The rules that govern MV and HV work

Utility-scale solar plants are generating facilities, and OSHA's 29 CFR 1910.269 for power generation, transmission and distribution applies to much of this work. Several requirements shape every job:

  • Qualified employees only. A qualified employee must be trained to tell exposed live parts from other equipment, determine nominal voltage, know and keep minimum approach distances, and use protective equipment and insulated tools. Training is not complete until the employer confirms you have demonstrated proficiency. Tasks done less than once a year require retraining first.
  • Job briefings. The person in charge briefs the crew before each job on hazards, procedures, precautions, energy controls and PPE.
  • Hazardous energy control. Only authorized employees doing the work apply and remove locks and tags, stored energy is relieved, and isolation is verified before work starts.
  • Minimum approach distances. The employer sets distances at least equal to OSHA's tables. For the 5.1 kV to 72.5 kV range, the distance combines a fixed inadvertent-movement factor with an electrical component that rises with voltage and altitude.
  • Arc-flash assessment. The employer must identify employees exposed to arc hazards and estimate incident heat energy. Where it exceeds 2.0 cal/cm2, clothing and equipment must carry an arc rating at least equal to the estimate.

Treat it as energized. Under 1910.269, lines and equipment are considered energized until they have been deenergized under the standard's procedures. On the MV side, that means a written switching order, verified isolation, testing and grounds before anyone touches a conductor.

Pay and outlook for MV and HV roles

The pay jump from DC-side technician to HV specialist is real. Here is what current sources show:

Role or benchmarkPaySource
Solar Technician I (Clearway)$54,000 to $77,000Employer posting
Solar Technician II (Clearway)$62,000 to $88,000Employer posting
Solar Technician III, with switching and clearance duties (Clearway)$88,000 to $107,000Employer posting
High Voltage Technician (Clearway)$95,000 to $110,000 plus bonusEmployer posting
Powerhouse, substation and relay electrical and electronics repairers, national median$103,020 (May 2025)BLS OOH

The BLS Occupational Outlook Handbook projects employment of powerhouse, substation and relay repairers to grow 10 percent from 2025 to 2035, from 20,900 to 22,900 jobs, and ties that demand to growing strain on the power grid. It is a small occupation, which is part of why experienced people are hard to find and well paid. BLS also notes many of these workers first gain experience as electricians.

How a solar O&M tech moves into substation work

The path is incremental. Nobody hands a new tech a 230 kV switching order. This is the sequence that matches how employers structure the work:

  1. Master the DC side and LOTO. Be the tech who never shortcuts a lockout. Supervisors choose people for HV training based on that habit.
  2. Get NFPA 70E training and arc-flash fluency. Clearway lists familiarity with 70E, arc-flash hazards, PPE and grounding and switching equipment as a requirement for its HV role.
  3. Ask to shadow switching. Clearway's Level III solar tech posting already includes preparing and carrying out switching and clearance orders with the operations center, and being qualified for routine and emergency operations in the switchyard. That is the bridge rung.
  4. Volunteer for outages. Annual substation outages bring in relay testers, transformer crews and breaker specialists. Work alongside them, carry their gear, ask what they are testing and why.
  5. Learn the test instruments. Insulation resistance testers, cable fault locators, power quality analyzers, thermal cameras. Our guide to thermography certification covers one of the listed skills.
  6. Get a commercial driver's license. Clearway requires a Class B for its HV role and prefers a Class A, because bucket and line trucks come with the job.
  7. Formalize the experience. Clearway asks for a completed formal apprenticeship or an equivalent mix of experience and technical training, and prefers journeyman lineman certification or direct substation experience.

NETA certification as a structured ladder

The InterNational Electrical Testing Association offers a technician certification that maps neatly onto this progression. According to NETA's certification page:

NETA levelExperienceTraining hoursExam
Level 1: TraineeNone listedNone listed; HS or GEDEmployer-administered
Level 2: Certified Assistant2 years40 safety, 160 electrical100 items, 2 hours
Level 3: Certified Technician5 years64 safety, 400 electrical (total)100 items, 2 hours
Level 4: Certified Senior Technician10 years104 safety, 600 electrical (total)65 items, 2 hours

Levels must be taken in order, the exams are closed-book and proctored, and two or more years of electrical technical education can count for up to one year of experience. NETA certification is most common among acceptance and maintenance testing firms, which are also the contractors solar sites hire for relay and breaker testing. That makes it useful both for moving up in-house and for moving to the testing side.

Is substation work the right move for you?

Use this quick self-check:

  • You like procedure. HV work is planned, written, checked and briefed. Improvisers struggle.
  • You can handle on-call. Clearway's HV posting asks about nights, weekends and holidays on call, plus short-term alternate shifts.
  • You are comfortable at height. The same application asks about climbing ladders up to 300 feet, a reminder that some sites share HV techs with wind.
  • You want transferable skills. Substation, relay and transformer experience moves to utilities, wind, storage, data centers and industrial plants.
  • You are patient. Five years of HV experience is the stated bar for the top role. Plan for it.

If remote sites and rural postings are part of the picture, our comparison of local and traveling O&M jobs helps set expectations.

Bottom line

Medium- and high-voltage work is the clearest pay ladder in solar O&M, with top field roles and the BLS substation benchmark both sitting around $100,000. Getting there takes years, not months: build a perfect safety record on the DC side, earn switching and clearance duties, work every outage you can, add NFPA 70E, a CDL and a structured credential such as NETA, and log your HV hours. Techs who do that become the people a plant cannot run without.

Gear mentioned in this guide

As an Amazon Associate, Jobs In Solar Tech earns from qualifying purchases. Prices and availability change; check current listings.

Frequently asked questions

How much does a solar substation technician make?

It depends on the employer and experience. Clearway Energy posts its High Voltage Technician role at $95,000 to $110,000 plus an annual bonus. BLS reports a May 2025 national median of $103,020 for powerhouse, substation and relay electrical and electronics repairers. Entry-level DC-side solar technicians typically start well below that, so the move to HV work is a significant raise.

What qualifications do you need for high voltage work at a solar farm?

Employers usually want several years of HV experience, NFPA 70E and arc-flash knowledge, and experience with switching, grounding, breakers, relays and transformers. One major owner asks for five years of HV experience, a formal apprenticeship or equivalent training, and a Class B CDL, and prefers journeyman lineman certification or direct substation experience.

What is NETA certification?

It is a four-level technician certification from the InterNational Electrical Testing Association for people who test and maintain electrical power equipment. Level 2 needs two years of experience and 200 training hours, Level 3 needs five years, and Level 4 needs ten. Levels 2 through 4 require closed-book, proctored exams, and levels must be earned in order.

Does OSHA 1910.269 apply to solar plants?

OSHA's 1910.269 standard covers the operation and maintenance of electric power generation, transmission and distribution equipment, and much of the medium- and high-voltage work at utility-scale solar plants falls under it. It requires qualified-employee training, job briefings, energy control procedures, minimum approach distances and arc-flash hazard assessments. Your employer's safety program defines exactly how it applies at your site.

Looking for solar o&m work?

Tell us your trade, location and experience. The Careers In Trades network routes you to employers who are actually hiring. Free for workers.

Sources

  1. OSHA — 29 CFR 1910.269, Electric Power Generation, Transmission, and Distribution
  2. BLS Occupational Outlook Handbook — Electrical and Electronics Installers and Repairers
  3. NETA — Technician Certification
  4. Clearway Energy Group — High Voltage Technician job posting
  5. Clearway Energy Group — Solar Technician job posting
  6. Wikipedia — Photovoltaic power station

Pay, licensing and program details change and vary by state, employer and local agreement. Verify with the linked sources and your state licensing board before making decisions.